AC Error CodesLG

LG AC Error Codes — Complete List & Fixes

LG split ACs show CH (check) codes on the indoor display. Dual-inverter models display the code directly; older models blink LEDs.

15 codes explained · DIY checks included · Same-day LG AC repair in Ahmedabad

👆 Select your AC brand and type the code shown on your AC display or remote

All LG AC Error Codes

CH01🔧 Needs Technician

Indoor air temperature sensor fault

Likely causes: Sensor open/short circuit

What to do: Sensor replacement — a quick technician fix.

📱 Book Same-Day Repair for CH01
CH02🔧 Needs Technician

Indoor pipe (coil) sensor fault

Likely causes: Coil thermistor failure

What to do: Needs sensor replacement.

📱 Book Same-Day Repair for CH02
CH05🔧 Needs Technician

Indoor-outdoor communication error

Likely causes: Interconnecting cable fault, PCB failure

What to do: Restart at the MCB once; if it returns, wiring and boards need testing.

📱 Book Same-Day Repair for CH05
CH06🔧 Needs Technician

Outdoor pipe sensor fault

Likely causes: Outdoor coil thermistor failure

What to do: Outdoor sensor replacement.

📱 Book Same-Day Repair for CH06
CH09🔧 Needs Technician

Indoor EEPROM error

Likely causes: Indoor PCB memory chip fault

What to do: PCB repair or replacement required.

📱 Book Same-Day Repair for CH09
CH10🔧 Needs Technician

Indoor fan motor lock / feedback error

Likely causes: Blower jammed, BLDC motor failure

What to do: Switch off and book a repair — check nothing is blocking the blower.

📱 Book Same-Day Repair for CH10
CH21🚨 Urgent - Switch Off AC

DC peak overcurrent (compressor)

Likely causes: Compressor or inverter PCB fault

What to do: Switch off the AC and call for service.

📱 Book Same-Day Repair for CH21
CH23🔧 Needs Technician

DC link low voltage

Likely causes: Low mains voltage, faulty inverter board

What to do: Check supply voltage/stabilizer first; if normal, the inverter board needs testing.

📱 Book Same-Day Repair for CH23
CH26🚨 Urgent - Switch Off AC

DC compressor position error

Likely causes: Compressor startup failure

What to do: Needs inverter and compressor diagnosis.

📱 Book Same-Day Repair for CH26
CH32🔧 Needs Technician

Discharge pipe temperature too high

Likely causes: Low gas, blocked condenser

What to do: Clean the outdoor unit; if the error returns, gas pressure must be checked.

📱 Book Same-Day Repair for CH32
CH38🔧 Needs Technician

Refrigerant leak detected

Likely causes: Gas leak in piping or coil

What to do: Leak detection and repair needed — do not just top up gas.

📱 Book Same-Day Repair for CH38
CH44🔧 Needs Technician

Outdoor air sensor fault

Likely causes: Ambient thermistor failure

What to do: Outdoor sensor replacement.

📱 Book Same-Day Repair for CH44
CH61✅ Try DIY First

Condenser coil temperature high

Likely causes: Dirty condenser, poor ventilation around outdoor unit

What to do: Clean the condenser coil and clear space around the outdoor unit.

📱 Book Same-Day Repair for CH61
CH62🔧 Needs Technician

Heatsink temperature high

Likely causes: Inverter heatsink clogged with dust

What to do: Outdoor unit deep-clean required.

📱 Book Same-Day Repair for CH62
CH67🔧 Needs Technician

Outdoor fan motor lock

Likely causes: Fan obstruction or motor failure

What to do: Check for obstructions; otherwise the fan motor needs replacement.

📱 Book Same-Day Repair for CH67

Disclaimer: error codes can vary by model and year. This guide covers the most common LG split AC codes in India. When in doubt, send us a photo of your AC display on WhatsApp — diagnosis advice is free.

Other Brand Error Codes

Need your LG AC fixed today?

Expert technicians · Genuine parts · 3-month repair warranty · Serving all of Ahmedabad & Gujarat