All Daikin AC Error Codes

U0๐Ÿ”ง Needs Technician

Refrigerant shortage detected

Likely causes: Gas leak, blocked refrigerant piping

What to do: AC will cool poorly. Gas top-up alone is not a fix โ€” the leak must be found and sealed first.

๐Ÿ“ฑ Book Same-Day Repair for U0
U2โœ… Try DIY First

Supply voltage problem

Likely causes: Low/high mains voltage, power fluctuation

What to do: Check with a stabilizer or have your supply checked. Restart after voltage normalises.

๐Ÿ“ฑ Book Same-Day Repair for U2
U4๐Ÿ”ง Needs Technician

Indoor-outdoor transmission failure

Likely causes: Wiring fault, PCB failure, incorrect connection after relocation

What to do: Restart at the MCB once. If it repeats, the interconnecting cable and PCBs need testing.

๐Ÿ“ฑ Book Same-Day Repair for U4
A1๐Ÿ”ง Needs Technician

Indoor PCB defective

Likely causes: Board failure, moisture damage

What to do: Indoor control board replacement required.

๐Ÿ“ฑ Book Same-Day Repair for A1
A3โœ… Try DIY First

Drain level system abnormal

Likely causes: Clogged drain, faulty drain pump or float switch

What to do: Check for water around the indoor unit; drain cleaning usually resolves it.

๐Ÿ“ฑ Book Same-Day Repair for A3
A5โœ… Try DIY First

Freeze-up / high-pressure protection

Likely causes: Dirty filters, low gas, blocked airflow

What to do: Clean the air filters first. If the error returns, gas pressure needs checking.

๐Ÿ“ฑ Book Same-Day Repair for A5
A6๐Ÿ”ง Needs Technician

Indoor fan motor abnormal

Likely causes: Fan motor or motor driver failure

What to do: Needs fan motor inspection/replacement.

๐Ÿ“ฑ Book Same-Day Repair for A6
C4๐Ÿ”ง Needs Technician

Indoor heat-exchanger thermistor fault

Likely causes: Sensor failure or loose connector

What to do: Quick sensor replacement by a technician.

๐Ÿ“ฑ Book Same-Day Repair for C4
C9๐Ÿ”ง Needs Technician

Suction air thermistor fault

Likely causes: Room temperature sensor failure

What to do: Sensor replacement required; AC may overcool or undercool until fixed.

๐Ÿ“ฑ Book Same-Day Repair for C9
E1๐Ÿ”ง Needs Technician

Outdoor PCB defective

Likely causes: Outdoor control board failure

What to do: Outdoor board diagnosis and replacement.

๐Ÿ“ฑ Book Same-Day Repair for E1
E3๐Ÿšจ Urgent - Switch Off AC

High-pressure switch activated

Likely causes: Blocked condenser, outdoor fan failure, overcharge

What to do: Switch off and clean the outdoor unit. If it repeats, call for service immediately.

๐Ÿ“ฑ Book Same-Day Repair for E3
E5๐Ÿšจ Urgent - Switch Off AC

Compressor motor overload

Likely causes: High ambient temperature, low gas, failing compressor

What to do: Switch the unit off to prevent compressor damage and book a visit.

๐Ÿ“ฑ Book Same-Day Repair for E5
E6๐Ÿšจ Urgent - Switch Off AC

Compressor startup failure (lock)

Likely causes: Seized compressor, faulty starting components

What to do: Do not keep retrying โ€” call for service.

๐Ÿ“ฑ Book Same-Day Repair for E6
E7๐Ÿ”ง Needs Technician

Outdoor fan motor fault

Likely causes: Fan motor failure, obstruction

What to do: Check for visible obstruction in the outdoor fan; otherwise needs motor replacement.

๐Ÿ“ฑ Book Same-Day Repair for E7
F3๐Ÿ”ง Needs Technician

Discharge pipe temperature abnormal

Likely causes: Low refrigerant, blocked piping

What to do: Needs gas-pressure check by a technician.

๐Ÿ“ฑ Book Same-Day Repair for F3
H6๐Ÿ”ง Needs Technician

Compressor position sensor error

Likely causes: Sensor or inverter driver fault

What to do: Inverter board diagnosis required.

๐Ÿ“ฑ Book Same-Day Repair for H6
L5๐Ÿšจ Urgent - Switch Off AC

Inverter instantaneous overcurrent

Likely causes: Compressor short, inverter PCB failure

What to do: Switch off the unit and book an inspection.

๐Ÿ“ฑ Book Same-Day Repair for L5

Disclaimer: error codes can vary by model and year. This guide covers the most common Daikin split AC codes in India. When in doubt, send us a photo of your AC display on WhatsApp โ€” diagnosis advice is free.

Other Brand Error Codes

Need your Daikin AC fixed today?